Technical Specifications

Model

DS-120K-G01P3

-EU-AM8
DS-125K-G01P3
-EU-AM8
DS-130K-G01P3

-EU-AM8

DS-135K-G01P3
-EU-AM8
DS-136K-G01P3
-EU-AM8
Input Side
Max. DC Input Power(kW)180187.5195202.5204
Max. DC Input Voltage (V)1100
Start-up DC Input Voltage(V)250
MPPT Operating Range(V) 200~1000
Max. DC Input Current(A)40+40+40+40+40+40+40+40
Max. Short Circuit Current (A)60+60+60+60+60+60+60+60
No.of MPP Trackers
8
No.of Strings per MPP Tracker
4+4+4+4+4+4+4+4
Output Side
Rated Output Power(kW) 120 125 130 135 136
Max. Active Power(kW) 132 135 135 135 136
Rated Output Voltage/Range (V)
3L/N/PE 220/380V, 230/400V 0.85Un-1.1Un
(this may vary with grid standards)
Rated Grid Frequency(Hz) 50 / 60 (Optional)
Operating Phase Three phase
Rated AC Grid Output Current(A)
181.9/174
189.4/181.2
197/188.5
204.6/195.7
206.1/197.2
Max. AC Output Current(A)
200/191.4
204.6/195.7
204.6/195.7
204.6/195.7
206.1/197.2
Output Power Factor
>0.99
Total Harmonics Current Distortion (THDi)
<3%
DC Injection Current(mA) <0.5%
Grid Frequency Range 45~55 or 55~65 (Optional)
Efficiency
Max.Efficiency98.8%
Euro Efficiency98.3%
MPPT Efficiency>99%
Protection
DC Reverse-Polarity ProtectionYes
AC Short Circuit ProtectionYes
AC Output Overcurrent ProtectionYes
Output Overvoltage ProtectionYes
Insulation Resistance ProtectionYes
Ground Fault MonitoringYes
Islanding ProtectionYes
Temperature ProtectionYes
Integrated DC SwitchYes
Remote software uploadYes
Remote change of operating parametersYes
Surge protectionDC Type II / AC Type II
General Data
Cabinet Size (WxHxD mm)
1006×516×325.5 (Excluding Connectors and Brackets)
Weight(kg)103
TopologyTransformerless
Internal Consumption<1W (Night)
Running Temperature
-25~60, >45 Derating
Ingress ProtectionIP65
Noise Emission(Typical)
≤65 dB
Cooling ConceptSmart cooling
Permissible Altitude (m)
4000
Designed Lifetime>20 Years
Grid Connection Standard
IEC 61727, IEC 62116, CEI 0-21, CEI 0-16, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105, VDE-AR-N 4110
Operating Surroundings Humidity0-100%
Safety EMC/Standard        IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Features
Display LCD 240 × 160