iconsBuilt-in isolation transformer

VL series Solar TX 3P/3P 20KW

Built-in with isolation transformer, VL series Solar TX purifies input power to connected devices. It can be operated in three different operation modes, on-grid, off-grid and grid-tie with backup, depending on power requirements. InfiniSolar TX is a flexible and smart hybrid inverter which utilizes solar power, AC utility, and battery power source to supply continuous power. Besides, it can set power usage priority as self-consumption for maximizing your benefit.

Main Features

Technical Specifications

MODELVL series Solar TX-20KW
Maximum PV Input Power30KW
Rated Output Power20KW
Maximum Charging Power20KW
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage720 VDC / 950 VDC
Start-up Voltage / Initial Feeding Voltage500 VDC / 550 VDC
MPPT Voltage Range550 VDC ~ 900 VDC
Number of MPP Trackers/Max. Input Current1/48 Amp
Full power MPP Voltage Range625 VDC ~ 900 VDC
GRID OUTPUT (AC)
Output Frequency Range47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz
Nominal Output Voltage230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range184 – 265 VAC per phase
Nominal Output Current29 A per phase
Power Factor> 0.99
EFFICIENCY
Maximum Conversion Efficiency (DC/AC)91%
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage120-140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range170 – 280 VAC per phase
Maximum AC Input Current40 A per phase
PV INPUT (DC)
Maximum DC Power / Maximum DC Voltage30KW / 950 vdc
MPPT Voltage Range550 VDC ~ 900 VDC
Number of MPP Trackers/Max. Input Current1/48 Amp
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage230 VAC (P-N) / 400 VAC (P-P)
Output WaveformPure sine wave
Efficiency (DC to AC)>91%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage720 VDC / 950 VDC
Start-up Voltage / Initial Feeding Voltage500 VDC / 550 VDC
MPPT Voltage Range550 VDC ~ 900 VDC
Number of MPP Trackers/Max. Input Current1/48 Amp
GRID OUTPUT (AC)
Nominal Output Current29 A per phase
Nominal Output Voltage230 VAC (P-N) / 400 VAC (P-P)
Output Frequency Range47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz
Output Voltage Range184 – 265 VAC per phase
Power Factor> 0.99
AC INPUT
AC Start-up Voltage / Auto Restart Voltage120-140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range170 – 280 VAC per phase
Maximum AC Input Current40.0 A per phase
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage230 VAC (P-N) / 400 VAC (P-P)
Efficiency (DC to AC)>91%
BATTERY & CHARGER
Nominal Battery Voltage384 VDC
Maximum Charging Current50A
GENERAL
PHYSICAL
Dimension, D X W X H (mm)559 x 320 x 909
Net Weight (kgs)120
INTERFACE
Communication PortRS-232/USB
Intelligent SlotOptional SNMP, GRPS, WIFI, Modbus cards available
ENVIRONMENT
Humidity0 ~ 90% RH (No condensing)
Operating Temperature-10 to 55°C
Altitude0 ~ 1000 m**