iconsDual outputs for smart load management

VL series II TWIN 6KVA/6.2KVA

VL series II TWIN is designed with zero transfer time which is perfect for critical devices such as servers and ATMs. It’s equipped with a powerful 120A solar charger and 120A AC charger. The detachable LCD control module allows users to monitor this inverter remotely. It can also expand power capacity to 54KW/55.8KW with 9 units in parallel operation. VL series II TWIN is occupied with two outputs. The second output can be scheduled on/off, setting cut-off voltage or SOC and discharging time via LCD setting.

Main Features

Technical Specifications

MODELVL series II TWIN 6KVL series II TWIN 6.2K
Rated Power6000VA/6000W6200VA/6200W
Parallel CapabilityUp to 9 units
INPUT
Voltage230 VAC
Voltage Range110-280 VAC
Frequency Range50 Hz/60 Hz (Auto sensing) ± 4Hz
Power Factor≧ 0.98 @ Nominal Voltage (100% Load)
THDi≦ 10%
OUTPUT
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
WaveformPure sine wave
Harmonic Distortion≦3 % THD (Linear Load); ≦ 5 % THD (Non-linear Load)
Frequency Range (Synchronized Range)46~54 Hz or 56~64 Hz
AC Voltage Regulation (Line&Batt. Mode)230VAC ± 5%
Transfer Time (AC Mode to Batt. Mode)0ms
Transfer Time (Inverter to Bypass)4 ms (Typical)
EFFICIENCY
Battery Mode92%
ECO Mode98%
Line Mode94%
BATTERY
Battery Voltage40~66 VDC
Floating Charge Voltage54 VDC
Overcharge Protection66 VDC
PHYSICAL
Dimension, D X W X H (mm)140 x 295 x 468
Net Weight (kgs)12
Communication PortUSB/RS232/RS485/WI-FI/Dry-contact
OPERATING ENVIRONMENT
Operating Humidity5% to 95% Relative Humidity(Non-condensing)
Operating Temperature-10°C to 50°C
Storage Temperature-15°C to 60°C
SOLAR INPUT
Solar Charger typeMPPT
Maximum PV Array Power6000 W
MPPT Range @ Operating Voltage120 ~ 430 VDC
Maximum PV Array Open Circuit Voltage500 VDC
Maxmum Solar Charge Current120A
Maximum AC Charge Current120A