iconsHybrid inverter

VL series Solar 2KW-5KW

VL series Solar 2KW/3KW/5KW is a hybrid inverter which combines solar system, AC utility, and battery power source to supply continuous power. It is suitable for remote areas where the cost of utility is too high or emergency usage when utility is not stable.

Main Features

Technical Specifications

MODELVL series Solar 2KWVL series Solar Plus 3KWVL series Solar Plus II 3KWVL series Solar Plus 5KW
PHASE1-phase in/1-phase out
Maximum PV Input Power2250W4500W10000W
Rated Output Power2000W3000W5000W
Maximum Charging Power1200 W2880 W4800 W
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage300 VDC / 350 VDC360 VDC / 500 VDC720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage80 VDC / 120 VDC116 VDC / 150 VDC225 VDC / 250 VDC
MPPT Voltage Range120 VDC~320 VDC250 VDC~450 VDC250 VDC~850 VDC
Number of MPP Trackers/Max. Input Current1/1x15A1/1x18A2/2x10A
GRID OUTPUT (AC)
Nominal Output Voltage101/110/120/127 VAC208/220/230/240 VAC
Output Voltage Range88-127 VAC*184-265 VAC*
Nominal Output Current18A13A21A
Power Factor> 0.99
EFFICIENCY
Maximum Conversion Efficiency (DC/AC)95%96%
European Efficiency@Vnominal94%95%
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage60-70 VAC / 85 VAC120-140 VAC / 180 VAC
Acceptable Voltage Range80-130 VAC170-280 VAC
Maximum AC Input Current30A40A
PV INPUT (DC)
Maximum DC Voltage350 VDC500 VDC900 VDC
MPPT Voltage Range150 VDC~320 VDC250 VDC~450 VDC250 VDC~850 VDC
Number of MPP Trackers/Max. Input Current1/1x15A1/1x18A2/2x10A
BATTERY Mode Output (AC)
Nominal Output Voltage101/110/120/127 VAC202/208/220/230/240 VAC208/220/230/240 VAC202/208/220/230/240 VAC
Output WaveformPure Sine Wave
Efficiency (DC to AC)90%93%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage300 VDC / 350 VDC360 VDC / 500 VDC720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage80 VDC / 120 VDC116 VDC / 150 VDC225 VDC / 250 VDC
MPPT Voltage Range150 VDC~320 VDC250 VDC~450 VDC250 VDC~850 VDC
Number of MPP Trackers/Max. Input Current1/1x15A1/1x18A2/2x10A
GRID OUTPUT (AC)
Nominal Output Current18A13A21A
Nominal Output Voltage101/110/120/127 VAC202/208/220/230/240 VAC
Output Voltage Range88-127 VAC*184-264.5 VAC*
AC INPUT
AC Start-up Voltage / Auto Restart Voltage60-70 VAC / 85 VAC120-140 VAC / 180 VAC
Acceptable Voltage Range80-130 VAC170-280 VAC
Maximum AC Input Current30A40A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage101/110/120/127 VAC202/208/220/230/240 VAC
Efficiency (DC to AC)90%93%
BATTERY & CHARGER
Nominal DC Voltage48 VDC
Maximum Charging CurrentDefault 25A, 5A-25A (Adjustable)Default 25A, 5A-60A (Adjustable)Default 60A, 5A-100A (Adjustable)
GENERAL
PHYSICAL
Dimension, D X W X H (mm)107 x 438 x 480204.2 x 460x 600
Net Weight (kgs)15.529
INTERFACE
Communication PortUSB, RS-232
Intelligent SlotOptional SNMP, Modbus and AS-400 cards available
ENVIRONMENT
Operating Humidity0~90% RH (Non-condensing)
Operating Temperature0~40°C-10 to 55 °C
Altitude0~1000 m