VL series Solar Pump Inverter

The 3-phase in, 3-phase out solar pump inverter is environmentally friendly with a long lifetime and lower maintenance costs. Built-in MPPT ensures you to get the best output power and optimizes the performance of water pump solar Inverter along the day as it starts and stops automatically based on the intensity of solar radiation.

Main Features

Technical Specifications

MODELVL series 2.2KW LSVL series 2.2KW LSVL series 2.2KWVL series 7.5KWVL series 11KWVL series 15KW
Rated Output Power2200 W(3HP); (supports 0.75~3HP water pump)7500 W(10HP); (supports 3~10HP water pump)11000 W(15HP); (supports 10~15HP water pump)15000 W(20HP) (supports 10~20HP water pump)
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage320 VDC / 450 VDC540 VDC / 800 VDC800 VDC
Start-up Voltage120 VDC250 VDC
MPPT Voltage Range120 VDC~420 VDC250 VDC~780 VDC500 VDC~600 VDC
Number of MPP Trackers1
AC INPUT
Input Voltage220/230/240 VAC (-15%~+10%)N/A
Input Frequency47 Hz~63 HzN/A
OUTPUT
Nominal Voltage220/230/240 VAC3 x 220/230/240 VAC3 x 380/400/415/440 VAC
Efficiency> 97%
Nominal Output Current14 A10A5.0 A15 A22 A29A
Motor TypeSingle-phase (default)Three-phaseThree-phase asynchronous motor
Frequency Precision± 0.2%
PROTECTION
Full ProtectionPhase lost, dry pumping, motor locked, weak sunlight, over-voltage, under-voltage, over-current, surge, over-temperature and short circuit protection
ENVIRONMENT
Operating Temperature-20°C~45°C at 100% full load, 46°C~60°C power derating
Operating Humidity< 95% RH (No condensing)
PHYSICAL
Dimension, D X W X H (mm)110 x 230 x 342205 x 218 x 320
Net Weight (kgs)55.566.56
Type of Mechanical ProtectionIP20
INTERFACE
Communication PortRS-232/RS-485