With Ingress protection to IP65, VL series Solar WP 30kW is suitable for use both in outdoor applications and indoor environments where atmospheric moisture and dust are present. It supports 150% unbalance load and the maximum load is up to 15kw for each phase. This flexibility can facilitate various power consumption in a home environment. With built-In AC coupled function, the existing on-grid system can be easily upgraded and expanded to a hybrid system. VL series Solar WP 30Kw also offers a second terminal for the users choice as a generator input or a programmable output.
MODEL | VL series Solar WP 30KW | |
PHASE | 3-phase in/3-phase out | |
Maximum PV Input Power | 40000W | |
Rated Output Power | 30000 W | |
Maximum Charging Power | 18000 W | |
GRID-TIE OPERATION | ||
PV INPUT (DC) | ||
Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 1000 VDC | |
Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC | |
Number of MPP Trackers/Max. Input Current | A: 26A, B: 26A, C: 26A | |
MPP Voltage Range | 350 VDC ~ 900 VDC | |
Number of Strings Per MPP Tracker | A: 2, B: 2, C: 2 | |
GRID OUTPUT (AC) | ||
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | |
Output Voltage Range | 184 – 265 VAC per phase | |
Nominal Output Current | 43.5 A per phase | |
Power Factor | 0.9 lag ~ 0.9 lead | |
EFFICIENCY | ||
Maximum Conversion Efficiency (DC/AC) | 96.5% | |
European Efficiency@ Vnominal | 96% | |
OFF-GRID OPERATION | ||
AC INPUT | ||
AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC /180 VAC per phase | |
Acceptable Voltage Range | 170 – 280 VAC per phase | |
Maximum AC Input Current | 50 A | |
PV INPUT (DC) | ||
Maximum DC Voltage | 1000 VDC | |
Number of MPP Trackers/Max. Input Current | 3 / 26A per MPPT | |
MPP Voltage Range | 350 VDC ~ 900 VDC | |
BATTERY MODE OUTPUT (AC) | ||
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | |
Output Waveform | Pure sine wave | |
Efficiency (DC to AC) | 96% | |
HYBRID OPERATION | ||
PV INPUT (DC) | ||
Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC | |
Number of MPP Trackers/Max. Input Current | 3 / A: 26A, B: 26A, C: 26A | |
MPP Voltage Range | 350 VDC ~ 900 VDC | |
Maximum DC Voltage | 1000 VDC | |
GRID OUTPUT (AC) | ||
Nominal Output Current | 43.5 A per phase | |
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | |
Output Voltage Range | 184 – 265 VAC per phase | |
AC INPUT | ||
AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC /180 VAC per phase | |
Acceptable Voltage Range | 170 – 280 VAC per phase | |
Maximum AC Input Current | 50 A | |
BATTERY MODE OUTPUT (AC) | ||
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | |
Efficiency (DC to AC) | 96% | |
BATTERY & CHARGER | ||
Maximum Charging Current | 80 A | |
Battery Voltage Range | 500 ~ 1000 VDC | |
GENERAL | ||
PHYSICAL | ||
Dimension, D X W X H (mm) | 255 x 660 x 750 | |
Net Weight (kgs) | 73 | |
INTERFACE | ||
Communication Port | RS-232, USB, DRY CONTACT, RS-485 and Wi-Fi | |
Intelligent Slot | Optional SNMP, Modbus and GPRS cards | |
ENVIRONMENT | ||
Humidity | 0 ~ 100% RH (Non-condensing) | |
Operating Temperature | -25 to 60°C, > 45°C power derating | |
Altitude | 0 ~ 1000 m** |