With Ingress protection of IP65 - VL series Solar WP LV 6kW is fully protected against dust, airborne particles whilst and water jets which makes it suitable for use both in the indoor and harsh outdoor environment. It supports multiple input & output - split phase 208/240vac or single-phase 230vac.VL series Solar WP LV is also offering a second terminal for the users choice as a generator input or a programmable output.
MODEL | VL series Solar WP LV 6KW | |
Phase | 120/240V Split phase, 120V/208V Split phase | |
Maximum PV Input Power | 7500W | |
Rated Output Power | 6000VA/6000W | |
Maximum Charging Power | 6000W | |
GRID-TIE OPERATION | ||
PV INPUT (DC) | ||
Nominal DC Voltage / Maximum DC Voltage | 600 VDC | |
Start-up Voltage / Initial Feeding Voltage | 120VDC / 160 VDC | |
MPPT Voltage Range | 120 VDC ~ 550 VDC | |
Number of MPP Trackers/Max. Input Current | 2 / 15A | |
GRID OUTPUT (AC) | ||
Nominal Output Voltage | 110 VAC (P-N) / 220 VAC (P-P) | |
Output Voltage Range | 97-132VAC(P-N) / 194VAC-264VAC(P-P) | |
Nominal Output Current | 27.3 A per phase | |
Power Factor | 0.9 lag to 0.9 lead | |
EFFICIENCY | ||
Maximum Conversion Efficiency (DC/AC) | 96% | |
OFF-GRID OPERATION | ||
AC INPUT | ||
AC Start-up Voltage / Auto Restart Voltage | 85VAC(P-N), 170VAC(P-P) / 90VAC(P-N), 180VAC(P-P) | |
Acceptable Voltage Range | 85 – 140 VAC (P-N)/ 170 – 280 VAC (P-P) | |
Maximum AC Input Current | 30 A per phase | |
Frequency Range | 50 Hz/60 Hz (Auto sensing) | |
PV INPUT (DC) | ||
Maximum DC Voltage | 600 VDC | |
MPPT Voltage Range | 120 VDC ~ 550 VDC | |
Number of MPP Trackers/Max. Input Current | 2 / 15A | |
BATTERY MODE OUTPUT (AC) | ||
Nominal Output Voltage | 110 VAC (P-N) / 220 VAC (P-P) | |
Output Waveform | Pure Sine Wave | |
Efficiency (DC to AC) | 91% | |
HYBRID OPERATION | ||
PV INPUT (DC) | ||
Nominal DC Voltage / Maximum DC Voltage | 600 VDC | |
Start-up Voltage / Initial Feeding Voltage | 120VDC / 160 VDC | |
MPPT Voltage Range | 120 VDC ~ 550 VDC | |
Number of MPP Trackers/Max. Input Current | 2 / 15A | |
GRID OUTPUT (AC) | ||
Nominal Output Current | 27.3 A per phase | |
Nominal Output Voltage | 110 VAC (P-N) / 220 VAC (P-P) | |
Output Voltage Range | 97-132VAC(P-N) / 194VAC-264VAC(P-P) | |
AC INPUT | ||
AC Start-up Voltage / Auto Restart Voltage | 85VAC(P-N), 170VAC(P-P) / 90VAC(P-N), 180VAC(P-P) | |
Acceptable Voltage Range | 85 – 140 VAC (P-N)/ 170 – 280 VAC (P-P) | |
Maximum AC Input Current | 30 A per phase | |
BATTERY MODE OUTPUT (AC) | ||
Nominal Output Voltage | 110 VAC (P-N) / 220 VAC (P-P) | |
Efficiency (DC to AC) | 91% | |
Output Waveform | Pure sine wave | |
BATTERY & CHARGER | ||
Nominal DC Voltage | 42-62 VDC | |
Maximum Charging Current | 120 A | |
Maximum Solar Charging Current | 120 A | |
Maximum AC Charging Current | 120 A | |
GENERAL | ||
PHYSICAL | ||
Dimension, D X W X H (mm) | 215.5 x 515 x 700 | |
Net Weight (kgs) | 41 | |
INTERFACE | ||
Communication Port | RS232, RS485, WI-FI, USB | |
Parallel Function | Yes, 6 units | |
ENVIRONMENT | ||
Operating Temperature | ‘-25°C to 60°C (>45°C derating) | |
Protection Degree | IP 65 |